Technical performance and compliance with WT
TECHNICAL SPECIFICATIONS
Buildings compliant with the 2021 technical conditions.
Above-normal thermal insulation of partitions:
- Uc ≤ 0.17 W/(m2 - K) for walls
- Uc ≤ 0.12 W/(m2 - K) for the roof
- Uc ≤ 0.23 W/(m2 - K) for the floor
Air tightness of the building n₅₀ ≤ 0.6 1/h.
Fire resistance from REI 60 to REI 120 confirmed by Fire Classification issued by a notified body (ITB)
Floor load capacity from 5 kN to 20 kN
Sound insulation of walls:
- External wall with ventilated façade = 63 dB
- External wall with light wet facade = 52 dB
Wall bearing capacity:
- External wall 100 kg/m2
- Interior wall 50 kg/m2
Water resistance - the resistance of the materials used to the effects of moisture:
- swelling in thickness (24h) according to EN 317 not more than 1.5%.
- durability (resistance to moisture in cyclic test), i.e. reduction in tensile strength after cyclic test according to EN 319 and EN 321 not more than 0.3 N/mm2.
- swelling in thickness after cyclic test according to EN 317 and EN 321 not more than 1.5%.
Installations distributed in the partitions and in the false ceiling space
Room height from 3.0 to 3.7m (clear)
Possibility of phasing of works for future extension or superstructure
Possibility of redevelopment and change of the functional layout of the building in the future
Special rooms possible: hybrid room, MRI, CT scanner and others